Nitrogen Closed Cycle Spray Dryer

Loop sequence Atomized feed contacts heated nitrogen. Powder is separated and collected. The process gas passes through filtration and condensation;.

Organic Solvent Spray Dryer · AV-OSSD2L

Nitrogen Closed Cycle Spray Dryer

Loop sequence Atomized feed contacts heated nitrogen. Powder is separated and collected. The process gas passes through filtration and condensation;.

ModelAV-OSSD2L
BrandANVORE

Higher-throughput two-fluid spray drying with dual condensers and automatic filter cleaning

Nitrogen Closed Cycle Spray Dryer
Built for controlled solvent processing AV- OSSD2L expands laboratory closed-cycle processing with a 2 L product collection vessel, dual condensers and automatic filter cleaning. It is intended for solvent-bearing or oxidation-sensitive feeds that require nitrogen circulation instead of open-air drying. Oxygen-based feed control, pressure monitoring and adjustable airflow help operators establish a repeatable process window. Recommended use Best for laboratory scale-up, formulation optimization and small pilot batches requiring improved powder recovery. Process note Final solvent compatibility and operating conditions should be confirmed by a process-risk assessment.

Six Key Advantages

PRINCIPLE AND TECHNICAL DATA

Loop sequence Atomized feed contacts heated nitrogen. Powder is separated and collected. The process gas passes through filtration and condensation; recovered solvent is collected, and dry nitrogen returns through the blower and heater.

Feed solution Two-fluid orcentrifugal atomizer Heated nitrogen Drying chamber Powder separationand collection
Dry nitrogenreturns to heater Blower and heater Solvent collection Condenser Gas filtration

Technical Specifications

  • Specifications are based on the supplied source document and may change with configuration. Confirm utilities, materials of construction, solvent compatibility and compliance requirements before ordering.
Parameter Specification
Feed rate 50–3,000 mL/h
Product collection vessel 2 L
Inlet temperature Ambient to 300°C; ±0.5°C
Outlet temperature Ambient to 200°C; ±0.5°C
Chiller temperature −40°C; ±0.5°C
Atomization Two-fluid nozzle
Oxygen measurement 0–100%
Feed interlock Starts below 3% O₂ by default; setpoint adjustable
Pressure measurement 0–100 kPa
Automatic relief Above 0.02 MPa by default; setpoint adjustable
Airflow 0–150 m³/h; variable-frequency control
Fan power 2.2 kW
Drying chamber Ø350 × 1,020 mm
Filter bags 4; automatic pulse cleaning
Condensers 2 × 50 L; total area 5 m²
Heating power 7.5 kW
Overall dimensions 2200*1100*2400 cm L × W × H

Application Areas

  • Suitable applications depend on feed chemistry, solvent properties, required powder characteristics and site risk controls.
Nitrogen Closed Cycle Spray Dryer
Nitrogen Closed Cycle Spray Dryer
Nitrogen Closed Cycle Spray Dryer
Nitrogen Closed Cycle Spray Dryer
Nitrogen Closed Cycle Spray Dryer
Nitrogen Closed Cycle Spray Dryer
Pharmaceutical AP Is Solvent-based formulation and active-ingredient development. Battery Materials Electrode, electrolyte and functional material research.
Fine Chemicals Controlled drying of specialty chemical intermediates. Polymers and Resins Polymer, coating and resin process development.